Welcome to Warm Floor Comfort!


Anti fog mirror installation instructions

These instructions should be followed together with mirror manufacturer's installation instructions.

The heated mirror pad can be mounted directly on the back of the mirror, or mounted on the wall behind the mirror.

NOTE: READ ALL INSTRUCTIONS BEFORE STARTING.


Electrical

 heated mirror pads are UL approved, and are designed to be connected to the lighting circuit, wired direct to the light above the mirror, so that it is activated when the light is turned on. This circuit should be protected by a 20 amp fuse or circuit breaker at the distribution center. Wires

BLUE
GROUND (NEUTRAL)
BROWN
POSITIVE (LIVE)

All wiring must be covered and inaccessible in accordance with local safety and electrical codes.
The heated mirror pad must not be accessible once it is installed.

The electrical installation must be in accordance with the latest local electrical codes.

NOTE: IF IN DOUBT REGARDING THE ELECTRICAL CONNECTION, CONSULT A QUALIFIED ELECTRICIAN.

 


INSTALLATION 
FOR MOUNTING ON THE WALL

1. Hold the pad against the wall to determine the best location. The top of the pad should be slightly higher than the height of the tallest person who will be using the mirror. Position the pad vertically and horizontally, within the limits of the mirror, for optimum viewing. When this is complete, mark the corners and the wiring terminal block locations on the wall.

2. Cut out a recess in the wall for the terminal block, and a hole through the drywall for the wire. It should be large enough so that the heated mirror pad is flush against the wall when installed. This hole will be covered by the mirror, so allow yourself enough room for final mirror adjustment.

3. Pass the end of the wire through the hole and up into the electrical junction box for the vanity light.

4. Position the pad with the terminal block in the recess, and hold the pad in position with small pieces of tape at the four corners. The tape needs to hold the pad in position only until the mirror is in place.

5. Make the electrical connection See electrical notes and cautions on page 1. TURN OFF THE ELECTRICITY TO THE VANITY LIGHT, AT THE DISTRIBUTION CENTER, BEFORE DOING ANY ELECTRICAL WORK.

6. Place the mirror into position on the wall. Make sure that the mirror is flat against the wall.

7. Attach the mirror following the mirror manufacturer's instructions. If mirror mastic, or other adhesive is used for mounting, do not allow it to come into contact with the heated mirror pad. Instructions for mounting to the back of the mirror are attached to the pads.


IMPORTANT

TO AVOID DAMAGE TO THE MIRROR, AND IN COMMON WITH NORMAL PRACTICE, THE FOLLOWING POINTS SHOULD BE FOLLOWED.

1. Make certain that the wall is firm, flat, level and dry. Very important for mounting to the wall.

2. The mirror must be flat across its entire surface at all times to prevent cracking.

3. Screws must not be overly tightened and adjusted evenly to insure an even mirror.

4. Never rest anything against the mirror surface which will prevent the heat from dissipating fully and evenly.

5. If the heated mirror pad is to be installed behind irregular shaped mirrors, or if the mirror has been weakened in anyway, extra care must be taken not to create any excess stresses.

NOTE: The heated mirror pad must not be cut, or punctured, as this will damage the insulation, rendering it unsafe.

The  heated mirror pad is self regulating, designed to operate continuously with complete safety. As the ambient room temperature rises, so will the surface temperature of the mirror.

THE MANUFACTURER/SUPPLIER CANNOT BE HELD RESPONSIBLE FOR DAMAGE CAUSED BY IMPROPER INSTALLATION